File information:
File name:Braun_Oral_Line_Carioquenho_2008.rar
[preview Oral Line]
Size:2591 kB
Extension:rar
Mfg:Braun
Model:Oral Line 🔎
Original:
Descr:Outline and explosion device, service manual and catalog
Group:Electronics > Consumer electronics
Uploaded:10-01-2008
User:carioquenho
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:12
File name 3725.pdf

Service Documentation Braun Oral-B Interclean Market Release 8/96 ID 2 3725 3725 BINC Rev: 3/98 BAG Rev: 11/97 Service Documentation Exploded Drawing 3725 3725 - 2 BINC Rev: 3/98 BAG Rev: 11/97 Service Documentation Spare Parts List 3725 Part Description Handle, cpl. ID2 Tips Lid Container Spring catch Spring Trickle charger tower Wall attachment Trickle charger Brushheads Handle with timer Double trickle charger Pos. No. 1 2 3 4 5 6 7 8 9 10 11 12 Part Number 3725606 order by description 3725046 3725045 4726057 4726058 3725628 4728052 4728622 order by description 4713636 4727621 3725 - 3 BINC Rev: 9/96 BAG Rev: 8/96 Service Documentation Service Information 3725 Technical Data Voltage: Frequency: Power input: Power supply: 100 - 120 V 50 - 60 c/s approx. 1 Watt. battery, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). with rotating filament gum massager Sliding switch waterproof. Length without cleaning tip 19.5 cm, diameter 2.6 cm. Height 8.4 cm, length 4.1 cm, width 8.6 cm. approx. 25 minutes when unit fully charged. Charger, continuous operation: Cleaning tip: Flexi tip: Switch: Dimensions of the unit: Dimensions of the charger: Operating time: 3725 - 4 BINC Rev: 9/96 BAG Rev: 8/96 Service Documentation Service Information 3725 Preserving the rechargeable batteries To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 16 hours before the first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done every six months. Cell-Pack Recycling Braun Oral-B Intercleaner At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium-(NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · Fit the two slots on the bottom cap of the handle onto the protruding rim on the bottom of the charging unit. Turn the handle approximately 40° counterclockwise (direction of the arrow) to open it and take out cell. Do not incinerate. · Attention This product contains nickel-cadmium batteries. In the interest of protecting the environment, please do not dispose of the product in the household waste at the end of their useful life. Disposal can take place at appropriate collection sites provided in your area. 3725 - 5
File name 4712.pdf

Service Documentation Braun Oral-B Plaque Control Ultra Market Release 8/98 D 6011 4712 4712 BINC Rev: 8/98 BAG Rev: 5/98 Service Documentation Exploded Drawing 4712 4712 - 2 BINC Rev: 8/98 BAG Rev: 5/98 Service Documentation Spare Parts List 4712 Part Description Handle Brush Trickle charger basic Wall attachment Pos. No. 1 2 3 4 Part Number 4712637 EB 15 4728622 4728052 4712 - 3 BINC Rev: 8/98 BAG Rev: 5/98 Service Documentation Service Information 4712 Technical Data Voltage: Frequency: Power input: Appliance: 100 - 130 V 50 - 60 c/s approx. 1 Watts Plastic heat sealed. 2.4 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Multituft Oscillating brush movements 2800/min. approx. 60° Pressure switch watertight. Length without brush 17.5 cm, diameter 2.9 cm Height 8.4 cm, length 4.1 cm, width 8.6 cm. approx. 35 minutes when unit was fully charged. Power supply: Charger, continuous operation: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions of the charger: Operating time: Preserving the rechargeable batteries (NiCd) To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 16 hrs. before first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done at least every 6 months. 4712 - 4 BINC Rev: 8/98 BAG Rev: 5/98 Service Documentation Service Information 4712 Preserving the rechargeable batteries (NiMH) To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 32 hrs. before first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done at least every 6 months. Cell-Pack Recycling At the end of the time-of-use of this product, for environmental protection, the battery cell pack must be correctly recycled. For this purpose, the following steps are necessary: · Fit the slits on the bottom cap of the rechargeable power unit onto the protruding rim on the bottom of the recharger. Turn the rechargeable power unit approximately 60° in the direction of the arrow (anti-clockwise) as far as it will go. (see illustration) By applying pressure to the motor shaft, push cell pack with motor assembly out of the housing and tear off both thin connecting wires. Break off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. · · · Remove the battery and dispose of according to the local environmental regulations. The cells must never be thrown into fire or flame. Attention This product contains nickel cadmium or nickel hydride cells. In the interest of protecting the environment
File name 4713.pdf

Service Documentation Braun Oral- B Plak Control Market Release 2/96 Ultra D 9 4713 4713 BINC Rev: 7/96 BAG Rev: 2/96 Service Documentation Exploded Drawing 4713 4713 - 2 BINC Rev: 7/96 BAG Rev: 2/96 Service Documentation Spare Parts List 4713 Part Description Appliance with timer Brush Lid Brush container Spring catch Spring Trickle charger Wall attachment Pos. No. 1 2 3 4 5 6 7 8 Part Number 4713631 EBI 9 4728071 4728072 4726057 4726058 4728636 4728052 4713 - 3 BINC Rev: 7/96 BAG Rev: 2/96 Service Documentation Reference Drawing 4713 4713 - 4 BINC Rev: 12/98 BAG Rev: 2/98 Service Documentation Spare Parts List 4713 Part Description Appliance with timer Brush Lid Brush container Spring catch Spring Housing Wall attachment Pos. No. 1 2 3 4 5 6 7 8 Part Number 4713631 EBI 9 4726052 4726051 4726057 4726058 4726233 4728052 4713 - 5 BINC Rev: 7/96 BAG Rev: 2/96 Service Documentation Service Information 4713 Technical Data Voltage: Frequency: Power input: Appliance: 100 - 120 V 50-60 Hz Approx. 1 Watt Plastic, heat sealed. 2.4 Vdc motor. The transmission of power follows by way of gear train with eccenter to the shaft of the brush. 2 built-in batteries which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging with no danger of overloading. Signal by green LED. Multituft Oscillating brush movements Approx. 60° Pressure switch, watertight Length without brush 17.5 cm, diameter 2.9 cm Power Supply: Charger continuous operation: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions of the charger Unit with 2 brush bay: Unit with 4 brush bay: Operating time: Stop and go timer: Hgt. 15.5 cm, lg. 4.1 cm, wth. 8.6 cm Hgt. 16.6 cm, lg. 4.6 cm, wth. 8.8 cm Approx. 30 minutes when fully charged After two minutes of operation, the timer signals. The brush will turn off and at short intervals during a period of approx. 2 seconds. You can hear and feel that the minimum 2 minute brush time is over. 4713 - 6 BINC Rev: 7/96 BAG Rev: 2/96 Service Documentation Service Information 4713 Preserving the rechargeable batteries To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 16 hours before the first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done every six months. Cell-pack Recycling of Braun Oral-B Ultra Plaque Remover At the end of the time-or-use of this product for environmental protection, the nickel/cadmium-(NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary. Fit the two slits on the bottom cap of the rechargeable power unit onto the protruding rim on the bottom of the recharger. Turn the rechargeable power unit approximately 60° in the direction of the arrow (anti-clockwise) as far as it go (see illustration). By applying pressure
File name 4714.pdf

Service Documentation Braun Oral-B Plaque Remover Center Market Release 9/96 OC 9525 4714 4714 BINC Rev: 9/96 BAG Rev: 9/96 Service Documentation Exploded Drawing 4714 4714 - 2 BINC Rev: 11/97 BAG Rev: 9/96 Service Documentation Spare Parts List 4714 Part Description Lid Spring catch Spring Jet container Back housing Screw Foot Front housing Beaker Moving knob Handle with tube Switch knob End sleeve Motor Screw Sealing set Pump, cpl. Angle piece Transformer Screw Circuit board Wall bracket Jet set ED 5 (4 pieces) Padding Pos. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 19 20 22 23 24 25 26 27 Part Number 4723014 4525010 4525032 4723020 4723157 0031003 4803061 4714622 4714850 4723015 4714621 4714854 4803035 4723622 0034001 4723627 4714623 4714853 4723645 0031003 4723624 4723016 4723791 4723130 4714 - 3 BINC Rev: 9/96 BAG Rev: 9/96 Service Documentation Exploded Drawing 4714 4714 - 4 BINC Rev: 5/99 BAG Rev: 9/96 Service Documentation Spare Parts List 4714 Part Description Lid Spring catch Spring Brush container Housing Bottom, cpl. Ferrite core Screw Brush, EBI 9-3 Ultra Handle with timer Pos. No. 28 29 30 31 32 33 34 35 36 37 Part Number 4726052 4726057 4726058 4726051 4723012 4714625 4726063 0031135 order by description 4713631 4714 - 5 BINC Rev: 9/96 BAG Rev: 9/96 Service Documentation Service Information 4714 Technical Data Housing: Drive: Voltage: Wattage: Impulses (rpm): Feed performance: Filling capacity: Pressure regulator: Connecting hose: Operating time: Accessories: Plastic 15 V - direct current-motor with piston pump 120 V, 60 Hz 20 W 500 - 1000 / minute electronically adjustable 350 ml/minute in position 8 600 cm3 Infinitely variable (increasing 2-8) 0.25 - 0.7 N Spiral hose with connecting wire to switch, length 1 m (stretched) max. 20 minutes, 2 h cool-time 4 jets, jet container, wall bracket for appliance 4714 - 6 BINC Rev: 9/96 BAG Rev: 9/96 Service Documentation Service Information 4714 Disassembly · · · · · · · · Remove jet container (4) and beaker (9) loosen housing screws (6) and remove back housing (5). Pull mains through opening of back housing. Un-solder switch connectors in spots a and b from tube connections, slide end sleeve (13) on tube upwards and pull tube from pump connection. Carefully pull-out tube from front housing (8). Remove terminal connector from PCB (24) and remove adapter connector sideways out of front housing. Remove screws (23) from transformer (22) and take-out of front housing (8). Transformer with pump (19) including the corresponding O-rings and seals (16). Un-screw motor (14) from pump (19). Disengage angle piece (20) with seal (16e) from front housing. Loosen PCB (24) from front housing and pull-off from moving knob (10). Push moving knob out of front housing. Disengage lid (1) from front housing (snap-action). From handle with tube (11), the switch knob (12) can removed by sliding. Assembly The assembly is made in reversed sequence. Attention should be paid to the followi
File name 4715.pdf

Service Documentation Braun Oral-B OxyJet 3D Center / OxyJet Oral Irrigator Market Release 6/99 OC 15525X MD 15 4715 4715 BINC Rev: 2/00 BAG Rev: 6/99 Service Documentation Exploded Drawing 4715 OC 15 4715 - 2 BINC Rev: 2/00 BAG Rev: 6/99 Service Documentation Exploded Drawing 4715 MD 15 4715 - 3 BINC Rev: 2/00 BAG Rev: 6/99 Service Documentation Spare Parts List 4715 Part Description Lid Back housing Mounting set Front housing Beaker cpl. Regulating switch cpl. Handle cpl. Pump cpl. Set of small parts (9a ­ 9j) Elbow Transformer cpl. PCB cpl. Air filter cpl. Air filter cpl. Hose clamp Lid Back housing Front housing Transformer cpl. PCB cpl. Coil cpl. Jet container Brush container EB 15 irrigator tips EB 15 brush heads Handle (single speed) Handle (two speed) Pos. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 21 22 23 24 25 26 30 40 50 60 100 100 Part Number 4715660 4715665 4715646 4715644 4715647 4715648 4715657 4715649 4715650 4715651 4715666 4715658 4715655 4715656 4715677 4715661 4715667 4715645 4715668 4715659 4715652 4715654 4715653 order by description order by description 4729630 4729635 4715 - 4 BINC Rev: 9/99 BAG Rev: 6/99 Service Documentation Service Information 4715 Technical Data Nominal voltage: Nominal power: Drive: Impulses (rpm): Feed performance: Filling capacity: Operating pressure: Connecting hose: Operating time: Auto turn off: 120 V, 50 - 60 Hz approx. 25 W 15 V ­ direct current motor with piston pump 700 ­ 1150 strokes/min electronically adjustable 300 ml/min when control switch is in position 5 600 cm3 8 bar max. Spiraled, straight length approx. 1 meter max. 15 minutes, 2 hr. cool-time The appliance is provided with an automatic turn off Response time: Reset: Air filter This appliance is provided with an air filter (13) which is placed at the appliance's front side. There is no need to maintain this filter regularly. In case this air filter must be replaced, the appliance does not need to be dismantled. In order to remove the complete air filter unit, you merely have to turn it 45° to the left side then pull it to the front. The reassembly is done in reverse order, thereby making sure the cleaner is placed horizontally. Since the filter is difficult to grip, we recommend using a suitable device such as a chamois. Special screws The special screws (9d) used in this appliance can only be unscrewed by means of a special screw driver blade. Safety torx T­10. 10 min On/off switch has to be pressed twice 4715 - 5 BINC Rev: 9/99 BAG Rev: 6/99 Service Documentation Service Information 4715 Disassembly · · · Remove jet container (30), brush container (40) and beaker cpl. (5). Carefully unhinge the lid (1 resp. 21) from the notches in the front housing (4 resp. 23) and remove it. Untighten the upper housing screw (positioned in the housing back below the spring catch). This makes the spring catch (9a) slide out of the housing to such an extent, that it can be removed ­ together with the spring (9b) ­ without any pr
File name 4723.pdf

Service Documentation Braun Plak Control Center Market Release 10/91 OC 5 4723 4723 BINC Rev: 9/99 BAG Rev: 11/97 Service Documentation Exploded Drawing 4723 4723 - 2 BINC Rev: 9/99 BAG Rev: 11/97 Service Documentation Spare Parts List 4723 Part Description Lid Spring catch Spring Jet container Back housing (old) Back housing (new, see page 9) Screw Foot Front housing Front housing (new, see page 9) Beaker Moving knob Handle with tube Switch knob End sleeve Motor Screw Sealing set Pump, cpl. Angle piece Transformer Transformer (new, see page 9) Holder for plug contacts Screw Circuit board Wall bracket Jet set ED 5 (4 pieces) Padding Pos. No. 1 2 3 4 5 5 6 7 8 8 9 10 11 12 13 14 15 16 19 20 22 22 22a 23 24 25 26 27 Part Number 4723014 4525010 4525032 4723020 4723095 4723147 0031072 4803061 4723632 4723641 4714850 4723015 4723640 4723912 4803035 4723622 0034001 4723627 4714623 4723046 4723630 4723645 4723121 0031122 4723624 4723016 4723791 4723130 4723 - 3 BINC Rev: 9/99 BAG Rev: 11/97 Service Documentation Exploded Drawing 4723 4723 - 4 BINC Rev: 9/99 BAG Rev: 11/97 Service Documentation Spare Parts List 4723 Part Description Lid Spring catch Spring Brush container Housing Bottom, cpl. Ferrite core Screw Brusheads D 5 Handle without timer D 5 Handle with timer Handle without timer Handle with timer Pos. No. 28 29 30 31 32 33 34 35 36 37 37 38 38 Part Number 4726052 4726057 4726058 4726051 4723012 4714625 4726063 0031135 EBI 15 4726630 4726631 4730630 4730631 4723 - 5 BINC Rev: 7/96 BAG Rev: 1/96 Service Documentation Service Information 4723 Technical Data Housing: Drive: Voltage: Wattage: Impulses (rpm): Feed performance: Filling capacity: Pressure regulator: Handle: Connecting hose: Operating time: Accessories: Plastic 15 V - direct current-motor with piston pump 120 V, 50 - 60 Hz 20 W 500 - 1000 / minute electronically adjustable 350 ml/minute in position 8 600 cm3 Infinitely variable (increasing 2-8) 0.25 - 0.7 N With waterproof appliance with impulse press key Spiral hose with connecting wire to switch, length 1 m (stretched) max. 20 minutes, 2 h cool-time 4 jets, jet container, wall bracket for appliance 4723 - 6 BINC Rev: 7/96 BAG Rev: 1/96 Service Documentation Service Information 4723 Disassembly · · · · · · · · Remove jet container (4) and beaker (9) loosen housing screws (6) and remove back housing (5). Pull mains through opening of back housing. Un-solder switch connectors in spots a and b from tube connections, slide end sleeve (13) on tube upwards and pull tube from pump connection. Carefully pull-out tube from front housing (8). Remove terminal connector from PCB (24) and remove adapter connector sideways out of front housing. Remove screws (23) from transformer (22) and take-out of front housing (8). Transformer with pump (19) including the corresponding O-rings and seals (16). Un-screw motor (14) from pump (19). Disengage angle piece (20) with seal (16e) from front housing. Loosen PCB (24) from front hou
File name 4725.pdf

Service Documentation Braun Plak Control Travel Market Release 8/92 D 5525 T D 5525 TS 4725 4725 BINC Rev: 7/96 BAG Rev: 9/92 Service Documentation Exploded Drawing 4725 4725 - 2 BINC Rev: 8/98 BAG Rev: 5/94 Service Documentation Spare Parts List 4725 Part Description Part Number Pos. No. D 5525 T 1 2 2 3 4 5 D 5525 TS 11 11 12 Protective cap Handle Handle with timer Switching plate Trickle charger Brush case Ring for power cord 4725626 4726630 4730631 4726860 4725623 4725625 4725029 Handle Handle with timer Protective cap 4730630 4730631 4725630 4725 - 3 BINC Rev: 7/96 BAG Rev: 9/93 Service Documentation Service Information 4725 Rechargeable unit Plastic, heat sealed, 2.4 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Line voltage: 110 - 240 V/50-60 c/s without selecting switch. Power input approx. 1 watt. Multituft, case for brushes Oscillating brush movements approx. 70° Magnetic switch (reed switch), watertight. Pressure switch, watertight. Length without brush 18.5 cm, diameter 3.2 cm. Height 3.8 cm, length 8 cm, width 3.2 cm. approx. 45 minutes when unit was fully charged. is equipped with an optical 2-minute timer, indicated by a red LED. Technical Data Appliance: Power supply: Charger, continuous operating: Brushes: Brush function: Angle of oscillation: Switch D 50: Switch D 50 S: Dimensions of the unit: Dimensions of the charger: Operating time: Plak control timer only: Cell-Pack Recycling of Braun-Plak Control At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium (NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · · · · Put appliance into the trickle charger and break-off lower cap (see illustration). By applying pressure to the motor shaft, push cell pack with motor assembly out of housing and tear-off both thin connecting wires. Break-off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. Remove cell pack out of plastic tube and dispose cells according to local laws or applicable environmental regulations for correct material separation and recycling. The cells must never be thrown into fire or flame. 4725 - 4
File name 4726.pdf

Service Documentation Braun Oral- B Plak Control Market Release 11/94 D5 4726 4726 BINC Rev: 4/98 BAG Rev: 12/97 Service Documentation Exploded Drawing 4726 4726 - 2 BINC Rev: 4/98 BAG Rev: 12/97 Service Documentation Spare Parts List 4726 Part Description Lid Spring catch Spring Brush container Housing Trickle charger Handle without timer Handle with timer Switching plate Brush, single pack Brush, 3 pack Wall attachment Housing for trickle charger Pos. No. 1 2 3 4 5 6 7 7 8 9 9 10 12 Part Number 4726052 4726057 4726058 4726051 4726233 4726632 4726630 4726631 4726860 EBI 9 /1 EBI 9 /3 4726054 NLA 4726 - 3 BINC Rev: 4/98 BAG Rev: 12/97 Service Documentation Service Information 4726 Technical Data Voltage Frequency Power input approx. Appliance: 100 - 120 V 50 - 60 Hz 1 Watt Plastic, heat sealed 2.4 V - DC - motor The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries which can be recharged by inductive continuous operating charger. (without contact). It compensates the loss of charge in the daily use-continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Multituft Oscillation ring brush movements approx. 70 ° Magnetic reed switch, watertight Length without brush 18.5 cm, diameter 3.2 cm. Height 17 cm, length 4.65 cm, width 9.0 cm. approx. 45 minutes when unit was fully charged. is equipped with an optical 2-minute timer, indicated by a red LED. When the capacity of the cells is running empty the power unit fails to function immediately. This protects the rechargeable cells from deep discharging. This maintains the motors full power capacity, The power unit should always be stored in the plugged in charging unit after use. The empty capacity is not comparable to a defective power unit. 4726 - 4 Power supply: Charger, continuous operating: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions or the charger. Operating time: Plak control timer only: Indication: BINC Rev: 4/98 BAG Rev: 12/97 Service Documentation Service Information 4726 Cell-Pack Recycling of Braun-Plak Control At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium(NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · Put appliance including lower cap into the opening (located in the back of the charger) and break-off lower cap (see illustration). · By applying pressure to the motor shaft, push cell pack with motor assembly out of housing and tear-off both thin connecting wires. Break-off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. Remove cell pack out of plastic tube and dispose cells according to local laws or applicable environmental regulations for correct material separation and recycling. The cells must never be thrown into fire or flame. · · Attention: This product contains nickel-cadmium
File name 4727.pdf

Service Documentation Braun Oral- B Plak Control duo Market Release 1/95 D7 4727 4727 BINC Rev: 7/96 BAG Rev: 1/95 Service Documentation Exploded Drawing 4727 4727 - 2 BINC Rev: 4/97 BAG Rev: 1/95 Service Documentation Spare Parts List 4727 Part Description Handle Handle with timer Double trickle charger Wall attachment Brush (single pack) Brush (three pack) Pos. No. 1 1 2 3 4 4 Part Number 4728630 4728631 4727621 4728052 EBI 9 /1 EBI 9 /3 4727 - 3 BINC Rev: 7/96 BAG Rev: 11/95 Service Documentation Service Information 4727 Technical Data Rechargeable unit Voltage Frequency Power input approx. Appliance: 100 - 120 V 50 - 60 Hz 2.5 Watts Plastic, heat sealed 2.4 V - DC - motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries which can be recharged by inductive continuous operating charger. (without contact). It compensates the loss of charge in the daily use-continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Multituft Oscillating brush movements approx. 70 ° Pressure switch, watertight. Length without brush 17.5 cm, diameter 2.9 cm. Height 8.3 cm, length 10.1 cm, width 7.3 cm. approx. 25 minutes when unit was fully charged. is equipped with an optical 2-minute timer, indicated by a red LED. Power supply: Charger, continuous operating: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions or the charger. Operating time: Plak control timer only: 4727 - 4 BINC Rev: 7/96 BAG Rev: 3/96 Service Documentation Reference Drawing 4727 Preserving the rechargeable batteries To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 16 hours before the first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done every six months. Cell-Pack Recycling of Braun-Plak Control At the end of the time-of-use of this product, for environmental protection, the nickel-cadmium(NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · Fit the two slits on the bottom cap of the rechargeable power unit onto the protruding rim on the bottom of the recharger. Turn the rechargeable power unit approximately 60° in the direction of the arrow (anti-clockwise) as far as it go, (see illustration). · · · By applying pressure to the motor shaft, push cell pack with motor assembly out of housing and tear-off both thin connecting wires. Break-off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. Remove cell pack out of plastic tube and dispose cells according to local laws or applicable environmental regulations for correct material separation and recycling. The cells must never be thrown into fire or flame. 4727 - 5
File name 4728.pdf

Service Documentation Braun Oral-B Plak Control Market Release 1/95 D7 4728 4728 BINC Rev: 7/96 BAG Rev: 7/95 Service Documentation Exploded Drawing 4728 4728 - 2 BINC Rev: 7/96 BAG Rev: 3/96 Service Documentation Spare Parts List 4728 Part Description Appliance without timer Appliance with timer Trickle charger Wall attachment Brush, EBI 5-1 Brush, EBI 5-3 Lid Spring catch Spring Brush container Trickle charger Pos. No. 1 1 2 3 4 4 5 6 7 8 9 Part Number 4728630 4728631 4728622 4728052 5897305 4730754 4728071 4726057 4726058 4728072 4728636 4728 - 3 BINC Rev: 7/96 BAG Rev: 5/95 Service Documentation Reference Drawing 4728 4728 - 4 BINC Rev: 7/96 BAG Rev: 5/95 Service Documentation Spare Parts List 4728 Part Description Appliance children's, blue Trickle charger Wall attachment Brush set EBI 5/3K Brush holder Pos. No. 1 2 3 4 5 Part Number 4728645 4728641 4728114 5897426 4728120 4728 - 5 BINC Rev: 7/96 BAG Rev: 11/95 Service Documentation Service Information 4728 Technical Data Voltage: Frequency: Power input: Appliance: 100 - 120 V 50 - 60 c/s approx. 1 Watt. Plastic heat sealed. 2.4 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Multituft Oscillating brush movements approx. 70° Pressure switch watertight. Length without brush 17.5 cm, diameter 2.9 cm. Power supply: Charger, continuous operation: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions of the charger: D 7011/ D 7521 K D 7025/ D 7525 Operating time: Plak control timer only: Stop and go timer: Height 8.4 cm, length 4.1 cm, width 8.6 cm. Height 15.5 cm, length 4.1 cm, width 8.6 cm. approx. 25 minutes when unit was fully charged. Is equipped with an optical 2-minute timer, (D 7011/7025/7525) indicated by a red LED. After one minute of operation the timer (D 7521 K) signals by short intervals of stop-n-go which last a few seconds. 4728 - 6 BINC Rev: 7/96 BAG Rev: 3/96 Service Documentation Service Information 4728 Preserving the rechargeable batteries To maximize the capacity and life of the rechargeable batteries, they should be fully charged for 16 hours before the first use and then fully discharged by normal use. Then recharge to full capacity again. The discharging/charging procedure should be done every six months. Cell-Pack Recycling Braun-plak Control At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium-(NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · Fit the two slits on the bottom cap of the rechargeable power unit onto the protruding rim on the bottom of the recharger. Turn the rechargeable power unit approximately
File name 4729.pdf

Service Documentation Braun Oral-B 3D Plaque Remover Market Release 8/98 D 15525 D 15525X 4729 4729 BINC Rev: 8/98 BAG Rev: 3/98 Service Documentation Exploded Drawing 4729 4729 - 2 BINC Rev: 8/98 BAG Rev: 3/98 Service Documentation Spare Parts List 4729 Part Description Appliance (15525) Appliance two speed (15525X) Brush Trickle charger tower Brush container Wall attachment Pos. No. 1 1 2 3 4 5 Part Number 4729630 4729635 EB 15 4729649 4729640 4729052 4729 - 3 BINC Rev: 8/98 BAG Rev: 3/98 Service Documentation Service Information 4729 Technical Data Voltage: Frequency: Power input: Appliance: 100 - 130 V 50 - 60 c/s approx. 2 Watts Plastic heat sealed. 1.2 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Multituft Oscillating brush movements 3800/min. approx. 56° Pressure switch watertight. The deluxe model features a reduced speed setting for sensitive areas of the mouth. Length without brush 19.0 cm, length 2.5 cm width 3.5 cm. Height 17.3 cm, length 4.8 cm, width 10.5 cm. Height 17.3 cm, length 4.8 cm, width 10.5 cm. approx. 30 minutes when unit was fully charged. After two minutes of operation the timer signals. The brush will turn off and at short intervals during a period of approx. 2 seconds. You can hear and feel that the minimum 2-minutes brushing time is over. An incorporated timer memorizes the elapsed brushing time, even when the handle is briefly (max. 30 seconds) switched off. 4729 - 4 Power supply: Charger, continuous operation: Brushes: Brush function: Angle of oscillation: Switch: Dimensions of the unit: Dimensions of the charger: D 15525 D 15525X Operating time: Stop and go timer: BINC Rev: 8/98 BAG Rev: 3/98 Service Documentation Service Information 4729 Preserving the rechargeable batteries After 16 hours the handle is fully charged. 30 minutes of operation time. To maintain your plaque remover's full power capacity, the handle should always be stored on the plugged in charging unit. Overcharging is impossible. Cell-Pack Recycling At the end of the time-of-use of this product, for environmental protection, the nickel hydride NH cell pack must be correctly recycled. For this purpose, the following steps are necessary: · · Open the bottom of the handle as shown, (see illustration) By applying pressure to the motor shaft, push cell pack with motor assembly out of the housing and tear off both thin connecting wires. Remove the battery and dispose of according to the local environmental regulations. The cells must never be thrown into fire or flame. · Attention This product contains nickel hydride cells. In the interest of protecting the environment, please do not dispose of the cells in the household
File name 4730.pdf

Service Documentation Braun Plak Control timer Market Release 3/91 D5 4730 4730 BINC Rev: 7/96 BAG Rev: 12/94 Service Documentation Exploded Drawing 4730 4730 - 2 BINC Rev: 7/96 BAG Rev: 3/95 Service Documentation Spare Parts List 4730 Part Description Lid Spring catch Spring Brush, container Housing Trickle charger Brush Wall attachment Handle Handle with timer Protective cap Brush case Pos. No. 1 2 3 4 5 6 9 10 11 11 12 Part Number 4726052 4726057 4726058 4726051 4726233 4726632 EBI 9 4726054 4730630 4730631 4725630 4725625 4730 - 3 BINC Rev: 7/96 BAG Rev: 7/94 Service Documentation Service Information 4730 Technical data Rechargeable unit Housing: Plastic, heat sealed, 2.4 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Line voltage: 120 V/ 60 Hz without selecting switch. Power input approx. 1 watt. Container for brushes. Multituft Oscillating brush movements approx. 70° Magnetic switch (reed switch), watertight. Pressure switch, watertight. Length without brush 18.5 cm, diameter 3.2 cm Height 17 cm, length 4.5 cm, width 9.7 cm. for charger approx. 45 minutes when unit was fully charged is equipped with an optical 2-minute timer. indicated by a red LED. Power supply: Charger, continuous operating: Brushes: Brush function: Angle of oscillation: Switch D 50: Switch D 50 5: Dimensions of the unit: Dimensions of the charger: Wall bracket: Operating time: Plak control timer only: Indication: When the capacity of the rechargeable cells is running empty the power unit fails to function immediately. This protects the rechargeable cells from deep discharging. The maintain the motors full power capacity, the power unit should always be stored in the plugged in charging unit after use. The empty capacity is not comparable to a defective power unit. It is important to check the capacity of the rechargeable cells before changing the power unit. 4730 - 4 BINC Rev: 7/96 BAG Rev: 6/94 Service Documentation Service Information 4730 Cell-Pack Recycling of Braun-Plak Control At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium (NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · · · · Put appliance including lower cap into the opening (located in the back of the charger) and break-off lower cap (see illustration). By applying pressure to the motor shaft, push cell pack with motor assembly out of housing and tear-off both thin connecting wires. Break-off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. Remove cell pack out of plastic tube and dispose cells according to local laws or applicable environmental re



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Braun KF16 - Braun House Line - Braun House Line - Braun House Line - Braun Braun Espresso Master Professional - Braun Braun Espresso Master Plus - BRAUN K 750 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung scx4300fw113

script execution: 0.36 s